Advertisement
Research Article| Volume 128, P29-35, October 2019

The effect of time interval of vaginal ring pessary replacement for pelvic organ prolapse on complications and patient satisfaction: A randomised controlled trial

      Highlights

      • This is the first study to assess the effect of different vaginal pessary replacement intervals for POP on complications and patient satisfaction.
      • A higher complication rate was found in the 6-monthly group compared with the 3-monthly group, but the difference was not statistically significant; patient satisfaction was high and similar in both groups.
      • The paper gives a detailed description of the study protocol, which can be used as a reference for future studies conducted at other centers.

      Abstract

      Objectives

      Limited data are available on the effect of the time interval of vaginal ring pessary replacement for pelvic organ prolapse (POP). This study investigated the effect of different replacement intervals on complications and patient satisfaction.

      Study design

      A double-blinded, randomized controlled trial was conducted in a tertiary urogynecology center. Women with a vaginal ring pessary for POP (stage I to IV) were randomly allocated to two groups: 3-monthly or 6-monthly ring pessary replacement. All women were blinded to the replacement interval. Investigators were blinded during outcome assessment. Subjects were followed up for 6 months.

      Main outcome measures

      The primary outcomes were the complication rates and patient satisfaction scores at 6 months. Secondary outcomes were the change in patient-reported symptoms and staging of POP.

      Results

      Of 101 women were screened from June 2016 to November 2017, 60 were recruited and randomly allocated: 30 to the 3-monthly replacement group and 30 to the 6-monthly replacement group. The overall complication rate in the 6-monthly group was higher than that in the 3-monthly group at the third visit (9 [30%] vs. 3[10.3%]; OR 3.71; 95%CI 0.89–15.58), but the difference was not statistically significant (p = 0.061). There were no statistically significant differences between groups in patient satisfaction scores, other prolapse-related symptoms or staging of POP.

      Conclusions

      We provide evidence on the effect of replacement interval for a vaginal pessary on complications and patient satisfaction. A higher complication rate was found in the 6-monthly group than in the 3-monthly group, although the difference was not statistically significant. Patient satisfaction scores were similar in both groups.

      Abbreviations:

      POP (pelvic organ prolapse), POP-Q (Pelvic Organ Prolapse-Quantification system), VAS (visual analogue scale), PVC (polyvinyl chlorine), BMI (body mass index)

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Maturitas
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Samuelsson E.C.
        • Victor A.
        • Tibblin G.
        • Svardsudd K.F.
        Signs of genital prolapse in a Swedish population of women 20 to 59 years of age and possible related factors.
        Am. J. Obstet. Gynecol. 1999; 180: 299-305
        • Olsen A.L.
        • Smith V.J.
        • Bergstrom J.O.
        • Colling J.C.
        • Clark A.L.
        Epidemiology of surgically managed pelvic organ prolapse and urinary incontinence.
        Obstet. Gynecol. 1997; : 501-506
        • Cundiff G.W.
        • Weidner A.C.
        • Visco A.G.
        • Bump R.C.
        • Addison W.A.
        A survey of pessary use by members of the American urogynecologic society.
        Obstet. Gynecol. 2000; 95: 931-935
        • Clemons J.L.
        • Aguilar V.C.
        • Tillinghast T.A.
        • Jackson N.D.
        • &Myers D.L.
        Patient satisfaction and changes in prolapse and urinary symptoms in women who were fitted successfully with a pessary for pelvic organ prolapse.
        Am. J. Obstet. Gynecol. 2004; 190: 1025-1029
        • Patel M.
        • Mellen C.
        • O’Sullivan D.M.
        • LaSala C.A.
        Impact of pessary use on prolapse symptoms, quality of life, and body image.
        Am. J. Obstet. Gynecol. 2010; 202 (499.e1-4)
        • Fernando R.J.
        • Thakar R.
        • Sultan A.H.
        • Shah S.M.
        • Jones P.W.
        Effect of vaginal pessaries on symptoms associated with pelvic organ prolapse.
        Obstet. Gynecol. 2006; : 93-99
        • Annie Hui S.Y.
        • Symphorosa Chan S.C.
        • Judy Lam S.Y.
        • Lau T.K.
        • Tony Chung K.H.
        A prospective study on the prevalence of hydronephrosis in women with pelvic organ prolapse and their outcomes after treatment.
        Int. Urogynecol. J. 2011; : 1529-1534
        • Cheung R.Y.K.
        • Lee J.H.S.
        • Lee L.L.
        • Chung T.K.H.
        • Chan S.S.C.
        Vaginal pessary in women with symptomatic pelvic organ prolapse.
        Obstet. Gynecol. 2016; 128: 73-80
        • Mao Meng
        • Ai Fangfang
        • Zhang Ye
        • Kang Jia
        • Liang Shuo
        • Xu Tao
        Lan Zhu. Changes in the symptoms and quality of life of women with symptomatic pelvic organ prolapse fitted with a ring with support pessary.
        Maturitas. 2018; 117: 51-56
        • Carol B.J.A.E.
        • Deepa G.
        • Fiona R.
        Pessaries (mechanical devices) for pelvic organ prolapse in women.
        Cochrane Database Syst. Rev. 2013; (CD004010)
        • Gorti M.
        • Hudelist G.
        • Simons A.
        Evaluation of vaginal pessary management: a UK-based survey.
        J. Obstet. Gynaecol. 2009; 29: 129-131
        • Sarma S.
        • Ying T.
        • Moore K.H.
        Long-term vaginal ring pessary use: discontinuation rates and adverse events.
        Bjog Int. J. Obstet. Gynaecol. 2009; 116: 1715-1721
        • Bai S.W.
        • Yoon B.S.
        • Kwon J.Y.
        • Shin J.S.
        • Kim S.K.
        • Park K.H.
        Survey of the characteristics and satisfaction degree of the patients using a pessary.
        Int. Urogynecol. J. 2005; 16: 182-186
        • Cheung I.
        • Lau W.
        Use of vaginal pessaries for pelvic organ prolapse in chinese women.
        Hong Kong J Gynaecol Obstet Midwifery. 2011; : 40-48
        • Jane Katherine
        • Penrose K.J.
        • Yin J.
        • Tsokos N.
        Delayed vesicovaginal fistula after ring pessary usage.
        Int. Urogynecol. J. Pelvic Floor Dysfunct. 2014; 25: 291-293
        • Arias B.E.
        • Ridgeway B.
        • Barber M.D.
        Complications of neglected vaginal pessaries: case presentation and literature review.
        Int. Urogynecol. J. Pelvic Floor Dysfunct. 2008; 19: 1173-1178
        • Komesu Y.M.
        • Rogers R.G.
        • Rode M.A.
        • Craig E.C.
        • Gallegos K.A.
        • Montoya A.R.
        • et al.
        Pelvic floor symptom changes in pessary users.
        Am. J. Obstet. Gynecol. 2007; 197 (620.e1–6)
        • Cundiff G.N.
        • Amudsen S.L.
        • Bent A.E.
        • Coates K.W.
        • Schaffer J.I.
        • Strohbehn K.
        • et al.
        The PESSRI study: symptom relief outcomes of a randomized crossover trial of the ring and Gellhorn pessaries.
        American Journal of Obstet and Gynco. 2007; 196 (405.e1-8)
        • Collins S.
        • Beigi R.
        • Mellen C.
        • O’Sullivan D.
        • Tulikangas P.
        The effect of pessaries on the vaginal microenvironment.
        Am. J. Obstet. Gynecol. 2015; 212 (60.e61-60.e66)
        • Yoshimura K.
        • Morotomi N.
        • Fukuda K.
        • Hachisuga T.
        • Taniguchi H.
        Effects of pelvic organ prolapse ring pessary therapy on intravaginal microbial flora.
        Int. Urogynecol. J. 2016; 27: 219-227
        • Fregosi Nicole J.
        • Hobson Deslyn T.G.
        • Kinman Casey L.
        • Gaskins Jeremy T.
        • Ryan Stewart J.
        • Meriwether Kate V.
        Changes in the vaginal microenvironment as related to frequency of pessary removal.
        Female Pelvic Med. Reconstr. Surg. 2018; 24: 166-171
        • Clemons J.L.
        • Aguilar V.C.
        • Tillinghast T.A.
        • Jackson N.D.
        • &Myers D.L.
        Patient satisfaction and changes in prolapse and urinary symptoms in women who were fitted successfully with a pessary for pelvic organ prolapse.
        Am. J. Obstet. Gynecol. 2004; 190: 1025-1029
        • Oliver R.
        • Thakar R.
        • Sultan A.H.
        The history and usage of the vaginal pessary: a review.
        Eur. J. Obstet. Gynecol. Reprod. Biol. 2011; 156: 125-130
        • Handa V.L.
        • Jones M.
        Do pessaries prevent the progression of pelvic organ prolapse?.
        Int. Urogynecol. J. 2002; 13 (discussion 352): 349-351
        • Dessie S.G.
        • Armstrong K.
        • Modest A.M.
        • Hacker M.R.
        • Hota L.S.
        Effect of vaginal estrogen on pessary use.
        Int. Urogynecol. J. 2016; 27: 1423-1429